IMPAC pyrometer IGA 15 plus
9
5 Display functions / Setting keys
Additionally to the temperature measurement the IGA 15 plus provides some more functions which
are necessary for a correct measurement and usefully enlarging the functionality of the pyrometer.
Temperature display
Parameter / function
Laser targeting light function on / off
Indication °C or °F
Parameter value / function value
Setting keys:
1) Parameter selection PAR
2) change of parameter values:  
Indication °C or °F: indicates the temperature in °C or °F.
Temperature display: shows the actual or stored temperature value.
Parameter / function: selecting a parameter or a measuring function for indication or changing a
corresponding short form will be displayed.
Parameter value / function value: indicates the value of the adjusted parameters or the tempera-
ture of the selected measuring function.
PAR key: Repeated pushing of the PAR key displays all available parameters (as EMI, HI, INT,
C/F) or additional measuring functions in the following sequence mentioned below. Parameters
are part of the basic settings of the pyrometer. They are only displayed during adjustment. Meas-
uring functions are displayed additionally to the measuring temperature (MAX, MIN, AVG, DIF),
can give an acoustic signal (HI) or can be used for data analysis (RCL). Selected measuring
functions are stored when the pyrometer is switched off and will be activated by restarting the
instrument.
PAR
Display
Parameter /
function
Short explanation
Factory
settings
1 x EMI Emissivity indication and setting of emissivity 100
2 x MAX Max. value indication of maximum value -
3 x MIN Min. value indication of minimum value -
4 x AVG Average indication of average value -
5 x DIF Difference
indication of the difference between the actual meas-
uring temperature and the start measuring temperature
-
6 x HI Hi alarm indication and setting of acoustic alarm 1800°C
7 x CLR Clear deletes the stored measured values
8 x STO
#
Store fixing of storage position
9 x RCL
#
Recall indication of stored measured values
10 x INT Interval
indication and setting of time interval for storage of
measured values in continuous mode
OFF
11 x C / F
Celsius
/
Fahrenheit
indication and setting of temperature reading
in °C or °F
C
Arrow keys:
With the arrow keys and the corresponding settings for all parameters can be changed. A
change in setting of a parameter is stored automatically.