2 Introduction
2.1 Appropriate use
The IS 320 and IGA 320 digital IMPAC pyrometers are designed for non-contact temperature
measurement of metals, ceramics, or graphite.
2.2 Scope of Delivery
Pyrometer, PC adjustment and evaluation software InfraWin, inspection sheet, and manual.
2.3 Technical Data
Temperature
Ranges:
IS 320:
550 ... 1400 °C (MB 14)
600 ... 1600 °C (MB 16)
650 ... 1800 °C (MB 18)
I
GA
320:
300 ... 1300 °C (MB 13)
350 ... 1650 °C (MB 16.5)
400 ... 1800 °C (MB 18)
Sub
R
ange:
A
ny range adjustable within the t
emperature range,
minimum span 51
°C
Spectral
R
ange:
IS 320:
0
.
8 ... 1
.
1 µm
IGA 320:
1
.
45 ... 1
.
8 µm
IR Detector:
IS 320:
Sili
con ph
otodiode (Si)
IGA 320: Indium Gallium Arsenide photodiode (InGaAs)
Power
S
upply:
24 V DC (10 to 30 V DC), ripple
must be
less than
0.5
V
Power
Consumption:
Max. 1 W
Analog
O
utput:
0 to 20 mA or 4 to 20 mA (linear), switchable
Load:
0 to 500
Switch
C
ontact:
Opto relays; max. 50 V DC, 0.2 A; max.
P
max
= 3
00 mW
Hysteresis:
2 to 20 °C
Digital Interface:
RS485 addressable (half duplex), baud rate 1200 up to 38400 Bd
Resolution:
0.1
°C on interface;
< 0.025% of the adjusted temperature sub range at the analog output
Isolation:
P
ower supply, analog output
,
and digital interface are galvanically
isolated from each other
Parameters:
Adjustable via interface:
Emissivity , transmittance , exposure time t
90
, clear times for max. / min.
value storage or automatically deletion of max. / min. value storage,
analog output 0 - 20 or 4 - 20 mA (switchable), sub temperature range,
ambient temperature compensation, address, switch contact, hysteresis,
baud rate, wait time t
W
Emissivity
:
10.0 to 100.0% adjustable via interface in steps of 0.1%
Transmittance :
10.0 to 100.0% adjustable via interface in steps of 0.1%
Exposure
T
ime
t
90
:
2 ms
(with dynamical adaptation at low signal levels);
adjustable to 0.01 s; 0.05 s; 0.25 s; 1 s; 3 s; 10 s
Maximum /
Minimum Value
Storage:
Built-in single or double storage. Clearing with adjusted time t
clear
(off; 0.01 s;
0.05 s; 0.25 s; 1 s; 5 s; 25 s), via interface or automatically with the next
measuring object
Uncertainty:
(with =1, t
90
=1 s,
T
amb.
=23°C)
Up to
1500
°C:
0.3% of
reading in °C + 1 °C
Above 1500 °C: 0.5% of reading in °C
(Note: the pyrometer must be in operation at least 30 min before these values are valid)
Seitenansicht 8